2 - Specifications EVIC

Electrical

Operating
Working Voltage Limits:9 - 24 VDC
Input Protection:

Input protected against reverse connection of supply. 

The nominal current draw of 300 mA @ 12 VDC.

Output Protection
Reverse Polarity:SAE J1455 2006 ed. 
Inductive Switching:SAE J1113-11 2006 ed. Test Pulse 1
ESD:SAE J1113-13 2004 e. Powered and Non-Powered.
CAN Interface
Protocol:CAN 2.0B 
Isolation:2.5kV VRMS Isolation (ISO1050DUB)
Baud Rates Supported:125, 250, 500 kbps and 1 Mbps
Digital Interfaces
Inputs:18V tolerant digital inputs, x8
Outputs:Low-side switching outputs up to 2A, x8
Analog Interfaces
Inputs:0-5V 12-bit resolution analog inputs, x5

Mechanical

 Operating Environment
Operating Temperature:-20°C to 70°C
Non-Operating Temperature:-30° to +80°C
Humidity:95%(non-condensing) at 40°C and 2% at 40°C
Ingress of Dust and Water:IP54
Performance
Vibration, Random:designed to meet SAE J1211 standards
Shock:designed to meet SAE J1211 standards
Weight
Weight:1.4 kg