Electrical
Operating |
---|
Working Voltage Limits: | 9 - 36 VDC |
Input Protection: | Input protected against reverse connection of supply. Nominal current draw 300 mA. |
Output Protection |
---|
Reverse Polarity: | SAE J1455 2006 ed. |
Inductive Switching: | SAE J1113-11 2006 ed. Test Pulse 1 |
ESD: | SAE J1113-13 2004 e. Powered and Non-Powered. |
CAN Interface |
---|
Protocol: | CAN 2.0B |
Isolation: | 2.5kV VRMS Isolation (ISO1050DUB) |
Baud Rates Supported: | 125, 250, 500 kbps and 1 Mbps |
Digital Interfaces |
---|
Inputs: | 18V tolerant digital inputs, x8 |
Outputs: | Low-side switching outputs up to 2A, x8 |
Analog Interfaces |
---|
Inputs: | 0-5V 12-bit resolution analog inputs, x5 |
Mechanical
Operating Environment |
---|
Operating Temperature: | -20°C to 70°C |
Non-Operating Temperature: | -30° to +80°C |
Humidity: | 95%(non-condensing) at 40°C and 2% at 40°C |
Ingress of Dust and Water: | IP54 |
Performance |
---|
Vibration, Random: | designed to meet SAE J1211 standards |
Shock: | designed to meet SAE J1211 standards |