Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Principle of Operation

...

EVIC decodes CAN bus data into human-readable form and displays it onto the HMI screen. EVIC is a standalone display device and is configurable with our Studio Interface Kit.

...

ConnectorManufacturerPins

Connector Part Number

Terminal Part Number

Power / CAN / Digital Input

Molex / Tyco2031408-12001393366-1 
Analog InputMolex / Tyco1231408-11201393367-1
Digital OutputMolex / Tyco1231408-11201393367-1

You can purchase these separately through Digi-key or Mouser, or request for them when you place your order.

This universal crimper tool can be used for the terminals.

General Set-up

To get started, wire Pins 1 and 3 (VBAT) to +12V or +24V and Pin 2 (GND) to Ground. Once power is applied, the default splash screen will be displayed and will transition to the Graphical User Interface (GUI) application.

...