Principle of Operation
...
EVIC decodes CAN bus data into human-readable form and displays it onto the HMI screen. EVIC is a standalone display device and is configurable with our Studio Interface Kit.
...
Connector | Manufacturer | Pins | Connector Part Number | Terminal Part Number |
---|---|---|---|---|
Power / CAN / Digital Input | Molex / Tyco | 20 | 31408-1200 | 1393366-1 |
Analog Input | Molex / Tyco | 12 | 31408-1120 | 1393367-1 |
Digital Output | Molex / Tyco | 12 | 31408-1120 | 1393367-1 |
You can purchase these separately through Digi-key or Mouser, or request for them when you place your order.
This universal crimper tool can be used for the terminals.
General Set-up
To get started, wire Pins 1 and 3 (VBAT) to +12V or +24V and Pin 2 (GND) to Ground. Once power is applied, the default splash screen will be displayed and will transition to the Graphical User Interface (GUI) application.
...