Skip to end of banner
Go to start of banner

2 - Specifications EVIC

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 17 Current »

Electrical

Operating
Working Voltage Limits:9 - 36 VDC
Input Protection:

Input protected against reverse connection of supply. 

The nominal current draw of 300 mA @ 12 VDC.

Output Protection
Reverse Polarity:SAE J1455 2006 ed. 
Inductive Switching:SAE J1113-11 2006 ed. Test Pulse 1
ESD:SAE J1113-13 2004 e. Powered and Non-Powered.
CAN Interface
Protocol:CAN 2.0B 
Isolation:2.5kV VRMS Isolation (ISO1050DUB)
Baud Rates Supported:125, 250, 500 kbps and 1 Mbps
Digital Interfaces
Inputs:18V tolerant digital inputs, x8
Outputs:Low-side switching outputs up to 2A, x8
Analog Interfaces
Inputs:0-5V 12-bit resolution analog inputs, x5

Mechanical

 Operating Environment
Operating Temperature:-20°C to 70°C
Non-Operating Temperature:-30° to +80°C
Humidity:95%(non-condensing) at 40°C and 2% at 40°C
Ingress of Dust and Water:IP54
Performance
Vibration, Random:designed to meet SAE J1211 standards
Shock:designed to meet SAE J1211 standards
Weight
Weight:1.4 kg
  • No labels