Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Operating
Working Voltage Limits:9 - 36 24 VDC
Input Protection:

Input protected against reverse connection of supply.

Nominal current draw 170 mA @ 12 VDC and 100 mA @ 24 VDC

...

 Operating Environment
Operating Temperature:-20°C to 70°C
Non-Operating Temperature:-30° to +80°C
Humidity:95%(non-condensing) at 40°C and 2% at 40°C
Ingress of Dust and Water:IP67IP64
Altitude (Barometric Pressure):101.3kPa to 18.6kPa

...

Performance
Vibration, Random:2h each axis to 2k Hz
Shock:11ms half-sine pulse of 490 m/s2 in 3-axis


Weight
Weight:1.36 kg*

Dimensions

...