Electrical

Operating
Working Voltage Limits:9 - 36 VDC
Input Protection:

Input protected against reverse connection of supply.

Nominal current draw 170 mA @ 12 VDC and 100 mA @ 24 VDC


Protection
Reverse PoloarityPolarity:SAE J1455 2006 ed. 
Inductive Switching:SAE J1113-11 2006 ed. Test Pulse 1
ESD:SAE J1113-13 2004 e. Powered and Non-Powered.

...

CAN Interface
Protocol:CAN 2.0B 
Isolation:2.5kV VRMS Isolation (ISO10500U8)
Baud Rates Supported:125, 250, 500 kbps and 1 Mbps
Digital Interfaces
Inputs:18V tolerant digital inputs, x6
Outputs:Low-side switching outputs up to 2A, x3
Analog InterfacesInputs:12-bit resolution analog inputs, x2

Mechanical

 Operating Environment
Operating Temperature:-20°C to 70°C
Non-Operating Temperature:-30° to +80°C
Humidity:95%(non-condensing) at 40°C and 2% at 40°C
Ingress of Dust and Water:IP67
Altitude (Barometric Pressure):101.3kPa to 18.6kPa

...

Performance
Vibration, Random:2h each axis to 2k Hz
Shock:11ms half-sine pulse of 490 m/s2 in 3-axis


Weight
Weight:1.36 kg*

Dimensions