2. There are configurable properties available for each analog input.

  • The "Factor" property allows you to multiply a value from the voltage signal received from the analog input. For example, there is a default value of "1", so the raw voltage from the analog-digital-converter (ADC) will be displayed within a range of 0-5V.
  • The "Unit" property allows you to set the text you want to be displayed with the value.

...

2. There are configurable properties available for each digital output.

  • The "CANSignal" property assigns any of the CAN signals available in your skin project to use in the Logic Setting 1, 2 and 3 properties. 
  • The "Triggers" property assigns any of the available IO or CAN signals in your skin project to determine what method to use prior to triggering the digital output.
  • The "Conditions" property assigns different logic statements (e.g., >=, <=, >, <) to compare with the actual IO or CAN signal data and the Value property.
  • The "Value" property assigns a value to compare with the Condition property.